COMING SOON
EXPANSE WHOLE
GENOME SEQUENCING
Consistent coverage at scale
- Home
- DNA NGS Solutions
Rethink PCR-free WGS
PCR-free whole genome sequencing delivers exceptional data quality, but achieving it at scale has required complex, time-intensive workflows. Expanse™ Whole Genome Sequencing brings PCR-free library preparation and breakthrough Cas9-mediated normalization together in a single integrated solution, with DNA inputs as low as 125 ng.
Go from DNA to a normalized, sequencing-ready library pool in approximately 2.5 hours, eliminating qPCR and manual normalization while delivering consistent coverage, fewer undercovered regions, and more efficient flow cell utilization. Enable predictable sequencing of up to 64 genomes on a NovaSeq X 25B flow cell, with less need for top-off and repeat sequencing.
Purpose-built for PCR-free WGS

Workflow Simplicity
Eliminate qPCR, dilution calculations, and manual normalization, taking you from DNA to a sequencing-ready library pool in approximately 2.5 hours.
A fully automatable workflow delivers balanced library representation with no off-deck handling.

Consistent Coverage at Scale
Robust normalization and even coverage uniformity enable samples to reliably achieve target depth, reducing undercoverage, top-offs, and repeat sequencing.
Supports up to 64 whole genomes at ≥30X coverage on a single NovaSeq X 25B flow cell.

More Data
Enrichment for sequencing-competent molecules and insert sizes optimized for 2x150 sequencing maximize usable flow cell output and coverage.

Sample Flexibility
Generates high-quality PCR-free genomes from clinically relevant sample types, including blood, saliva, and FFPE, with inputs as low as 125 ng.
Purpose-built for PCR-free WGS

Workflow Simplicity
Eliminate qPCR, dilution calculations, and manual normalization, taking you from DNA to a sequencing-ready library pool in approximately 2.5 hours.
A fully automatable workflow delivers balanced library representation with no off-deck handling.

Consistent Coverage at Scale
Robust normalization and even coverage uniformity enable samples to reliably achieve target depth, reducing undercoverage, top-offs, and repeat sequencing.
Supports up to 64 whole genomes at ≥30X coverage on a single NovaSeq X 25B flow cell.

More Data
Enrichment for sequencing-competent molecules and insert sizes optimized for 2x150 sequencing maximize usable flow cell output and coverage.

Sample Flexibility
Generates high-quality PCR-free genomes from clinically relevant sample types, including blood, saliva, and FFPE, with inputs as low as 75 ng.

Workflow Simplicity
Eliminate qPCR, dilution calculations, and manual normalization, taking you from DNA to a sequencing-ready library pool in approximately 2.5 hours.
A fully automatable workflow delivers balanced library representation with no off-deck handling.

Consistent Coverage at Scale
Robust normalization and even coverage uniformity enable samples to reliably achieve target depth, reducing undercoverage, top-offs, and repeat sequencing.
Supports up to 64 whole genomes at ≥30X coverage on a single NovaSeq X 25B flow cell.

More Data
Enrichment for sequencing-competent molecules and insert sizes optimized for 2x150 sequencing maximize usable flow cell output and coverage.

Sample Flexibility
Generates high-quality PCR-free genomes from clinically relevant sample types, including blood, saliva, and FFPE, with inputs as low as 75 ng.
Less Time. Less Complexity. Fewer Errors.


Figure 1. Streamline PCR-free WGS from DNA to pooled libraries. Expanse integrates library preparation and normalization into a fully automatable, ~2.5-hour workflow with no off-deck handling steps. By eliminating qPCR, dilution calculations, and manual pooling, the workflow reduces turnaround time, hands-on complexity, and opportunities for error.
Next-Generation Normalization
After library prep. There is a population of library molecules – only some of which are functional for sequencing.

Denaturation and extension. A second strand incapable of clustering has been synthesized.

Binding. The normalization reagent binds to extended molecules, capturing only functional library molecules.

Capture and elution. The bound DNA molecules are captured, all other DNA is washed away, and the normalized library is eluted and ready for sequencing.





Stay in touch for product updates
Sign up for updates on the upcoming launch of Expanse Whole Genome Sequencing Kits, including product availability, technical details, and early access opportunities.
Key Performance Data
Minimize undercoverage and top-off sequencing
Reaching 30X mean coverage doesn’t mean every sample or genomic region is adequately covered. Variability in PCR-free whole genome sequencing (WGS) can leave samples and challenging GC-rich regions undercovered, increasing the need for top-off or repeat sequencing.
Expanse delivers consistent WGS coverage and sequencing depth across sample types, DNA inputs, and challenging genomic regions, helping more genomes reach target coverage in the initial sequencing run.
Figure 2A. Consistent coverage across samples ...MORE
Figure 2B. Consistent coverage across samples ... MORE
Minimize undercoverage and top-off sequencing
Figure 2A. Consistent coverage across samples and challenging genomic regions. Expanse™ delivers consistent mean sequencing depth across sample types and DNA inputs, meeting the minimum 30X threshold. KAPA performance was affected by input-dependent differences in library fragment size, contributing to greater variability in sequencing depth across samples and inputs.
Libraries were prepared in duplicate from blood, saliva, and NA12878 reference DNA using Expanse PCR-free WGS, Twist PCR-free WGS, NEBNext® Ultra II FS DNA PCR-free, Illumina DNA PCR-Free, and KAPA EvoPlus V2 workflows. Libraries were grouped by library preparation method and sequenced 2x150 on individual lanes of a NovaSeq X 25B flow cell.
Figure 2B. Consistent coverage across samples and challenging genomic regions. Expanse™ maintains consistent whole-genome and GC-rich promoter coverage across samples and inputs, helping reduce undercovered regions that can drive top-off or repeat sequencing.
Libraries were prepared in duplicate from blood, saliva, and NA12878 reference DNA using Expanse PCR-free WGS, Twist PCR-free WGS, NEBNext® Ultra II FS DNA PCR-free, Illumina DNA PCR-Free, and KAPA EvoPlus V2 workflows. Libraries were grouped by library preparation method and sequenced 2x150 on individual lanes of a NovaSeq X 25B flow cell.
Designed to maximize sequencing output
Not every sequenced base translates into usable genome coverage. Non-functional library molecules and overlapping paired-end reads can reduce sequencing efficiency and consume valuable flow cell capacity.
Expanse enriches for sequencing-competent molecules and generates insert sizes optimized for 2x150 sequencing, reducing read overlap across sample types and DNA inputs. This translates to greater usable sequencing output, improved flow cell utilization, and more genome coverage from each PCR-free whole genome sequencing run.
Figure 3A. Maximize usable sequencing output ... MORE
Figure 3B. Maximize usable sequencing output ... MORE
Figure 3C. Maximize usable sequencing output ... MORE
Designed to maximize sequencing output
Figure 3A. Maximize usable sequencing output across sample types and DNA inputs Expanse™ generates consistent insert-size distributions across DNA inputs, with fragment sizes optimized for 2 × 150 sequencing.
Libraries were prepared in duplicate from blood, saliva, and NA12878 reference DNA using Expanse PCR-free WGS. Libraries were sequenced 2x150 on a NovaSeq X 25B flow cell.
Figure 3B. Maximize usable sequencing output across sample types and DNA inputs. Expanse™ generates longer inserts that reduce the proportion of sequenced bases lost to overlapping paired-end reads, increasing the amount of unique genomic information generated from each run.
Libraries were prepared in duplicate from blood, saliva, and NA12878 reference DNA using Expanse PCR-free WGS, Twist PCR-free WGS, NEBNext® Ultra II FS DNA PCR-free, Illumina DNA PCR-Free, and KAPA EvoPlus V2 workflows. Libraries were grouped by library preparation method and sequenced 2x150 on individual lanes of a NovaSeq X 25B flow cell.
Figure 3C. Maximize usable sequencing output across sample types and DNA inputs. Expanse™ enriches for sequencing-competent library molecules, increasing sequencing yield across sample types compared with traditional library preparation without enrichment.
Blood (400 ng), saliva (400 ng), FFPE (300 ng), and NA12878 (400 ng) were prepared using either a traditional library prep utilizing a qPCR quantification and pool approach or Expanse with integrated normalization. Each sample and library prep method combination was sequenced 2x150 on an individual NovaSeq X 25B lane to assess impact on lane output.
Integrated normalization delivers uniform library representation
Library quantification and normalization can add time and variability to PCR-free whole genome sequencing workflows. Expanse uses integrated Cas9-mediated normalization to balance library representation without qPCR, dilution calculations, or manual normalization. Across replicate sequencing lanes, Expanse delivers consistent sample representation, simplifying pooling while reducing variability in sequencing depth.


Figure 4. Balance libraries without qPCR normalization ... MORE
Integrated normalization delivers uniform library representation


Figure 4. Integrated normalization delivers consistent library representation across sequencing lanes. Expanse uses Cas9-mediated normalization to balance library representation without qPCR, dilution calculations, or manual normalization. Across replicate sequencing lanes, Expanse libraries show lower variability in sample representation compared with libraries normalized by qPCR, supporting more predictable sequencing depth and simplifying library pooling.
Libraries were generated from blood, saliva, and NA12878 reference DNA using inputs ranging from 100–500 ng. Expanse libraries were normalized using integrated PCR-free EquiPlex normalization, while comparator libraries were quantified by qPCR and manually normalized and pooled. Libraries were 2x150 sequenced on a NovaSeq X 25B flow cell.
High-quality libraries support accurate variant calling
Sequence accuracy is critical for confident variant detection, particularly as sequencing depth decreases. Expanse generates high-quality PCR-free libraries with low levels of library preparation artifacts and strong SNP variant-calling accuracy across sequencing depths. Higher F1 scores at lower read depths demonstrate robust variant-calling performance from fewer reads, with potential advantages for low-pass WGS applications.
Figure 5A. High-quality PCR-free libraries support accurate ... MORE
Figure 5B. High-quality PCR-free libraries support accurate ... MORE
High-quality libraries support accurate variant calling
Figure 5A. High-quality PCR-free libraries support accurate variant calling across sequencing depths. Expanse™ maintains strong SNP F1 scores as read count decreases, demonstrating robust variant-calling performance with fewer reads. KAPA generated shorter library fragments under the evaluated PCR-free workflow conditions, resulting in greater paired-end read overlap and less unique genomic information available for variant calling.
Libraries were prepared in duplicate from NA12878 reference DNA using Expanse PCR-free WGS, Twist PCR-free WGS, NEBNext® Ultra II FS DNA PCR-free, Illumina DNA PCR-Free, and KAPA EvoPlus V2 workflows.
Figure 5B. High-quality PCR-free libraries support accurate variant calling across sequencing depths. Expanse™ generates low levels of hairpin artifacts across all samples and inputs assessed, supporting high-quality sequence data for variant analysis.
Libraries were prepared in duplicate from blood, saliva, and NA12878 reference DNA using Expanse PCR-free WGS, Twist PCR-free WGS, NEBNext® Ultra II FS DNA PCR-free, Illumina DNA PCR-Free, and KAPA EvoPlus V2 workflows. Libraries were grouped by library preparation method and sequenced 2x150 on individual lanes of a NovaSeq X 25B flow cell.
Discover more with Watchmaker
DNA Library Prep Kits
A simple workflow that improves yields and coverage of low-input DNA samples, such as cfDNA...
mRNA Library Prep Kits
Prepare high-quality libraries in under 5 hours with as little as 2.5 ng...
RNA Library Prep Kits with Polaris® Depletion
Prepare libraries in under 4.5 hours with as little as 1 ng with a solution that includes tailored steps for FFPE processing...
For assay developers – make realizing your next product easier
- Navigate the complexities of productization with an experienced team who’s as committed to your success as you are
- All aspects of our customization process are designed to serve you with speed, agility, and above all else, a commitment to quality
- Tailored fill volumes, labeling (including white and private label), and packaging designed to your specifications
- All products are manufactured within an ISO 13485:2016-certified QMS (download our certificate)
- Home
- DNA NGS Solutions
- Expanse Whole Genome Sequencing